iCheck Chroma 3
iCheck Chroma 3™ is a state-of-the-art portable photometer for measuring vitamin A concentration in edible oil. The iCheck is specifically developed and equipped with innovative technology to enable technically sophisticated measurement of absorption. iCheck Chroma™ 3 displays vitamin A concentration in mg RE/kg and IU/g.
iCheck Chroma 3 measures vitamin A in oil
What is inside
iCheck Chroma 3: Case Content
iCheck device
Rechargeable batteries & charger
USB -B cable for data transfer
Vial stand
Chroma 3 Standard
USB stick with User Manual
User Manual
iCheck device
Rechargeable batteries & charger
USB -B cable for data transfer
Vial stand
Chroma 3 Standard
USB stick with User Manual
User Manual
A – iCheck device, B – Rechargeable batteries & charger, C – USB -B cable for data transfer, D – Vial stand, E – Chroma 3 Standard, F – USB stick with User Manual, G – User Manual.
iCheck Chroma 3: Test Kit Content
iCheck Chroma Reagent Vials x 100
1 mL syringe x 100
Needle x 100
iCheck Chroma Reagent Vials x 100
1 mL syringe x 100
Needle x 100
A – iCheck Chroma Reagent Vials x 100, B – 1 mL syringe x 100, C – Needle x 100.
Technical Specifications
Sample
| Analyte | Vitamin A (retinol) as retinyl palmitate |
| Sample | Refined edible oils: palm, soy, cottonseed, sunflower, corn, peanut, rapeseed, coconut, rice bran |
| Sample preparation | If the oil is solid, warm it up to a maximum of 50°C to make it liquid |
| Sample volume per analysis | 0.1 mL (100μL) |
| Concentration range | >3.0 ppm (mg/kg), samples above 30.0 ppm must be diluted in refined unfortified oil |
Device
| Analytical method | Photometric determination of retinol concentration using colorimetric Carr-Price reaction combined with compensation for matrix effect |
| Units displayed | mg RE/kg and IU/g; RE – retinol equivalents, IU – international units |
| Linear range | 3.00 – 30.00 mg RE/kg (10.00 – 100.00 IU/g) |
| Calibration | Factory set (standards included for control) |
| Time per analysis | < 2 min |
| Enviroment | 20 –30°C, no direct sunlight |
| Accuracy at 95% confidence interval at 25°C | <±30% |
| Method comparison | High-performance liquid chromatography (HPLC) |
| User training | 1 day training |
| Use | Laboratory and field |
| Data output | Sample #, Batch #, Result, Date, Time (in transferred data) |
| Connectivity and data | Results are stored in the device and transferred to a PC via USB |
| NiMH rechargeable batteries included; AA 1.2 or 1.5V | 2 years |
| Warranty | 2 years |
| Device weight | 0.45 kg |
| Device dimensions | 11 x 4 x 20 cm (W x H x L) |
Test Kit
| Content | 100 reagent vials; 100 syringes – 1.0 mL; 100 needles – 0.8mm x 16mm. |
| Chemical composition | Chloroform and antimony trichloride |
| Volume per reagent vial | 2.0 mL |
| Shelf life | 12 months at 20 – 30°C, no direct sunlight, upright |
| Dimension of test kit | 26 x 14.5 x 16.5 cm |
| Disposable instructions | Hazardous waste |
| Optional equipment | 50 mL falcons, reference samples |
More Information
-
Product flyer (English) Download PDF
-
User Manual (English) Download PDF
-
SOP: Measuring Vitamin A in Premix for Edible Oil with iCheck Chroma 3 (English) Download PDF
-
Technical Communication: iCheck Chroma 3 Validation in Edible oil Download PDF
-
Evidence Base: Comparitive Study of iCheck Chroma3 and HPLC for Quantifying Vitamin A in Edible Oils Download PDF
-
Application Material: Measurement of Vitamin A in Refined Edible Oils with iCheck Chroma 3 Download PDF
-
Getting Started with iCheck Chroma 3 Download PDF
-
FAQ Go to Page
Please visit our Technical Resources page to access technical materials such as product information, preparation instructions, application materials, and publications.
Accessories
What customers and partners are saying